Dillon Mains Power Supply with RS-232 Interface AWT25-501124
The Dillon AWT25-501124 is a dual-function mains power supply that provides both continuous 5V DC power and RS-232 serial communication interface for Dillon EDXtreme RED dynamometers, Communicator II remote displays, and Quick Check tension meters. This universal input power supply (100-240 VAC) eliminates the need for battery power while simultaneously enabling direct PC communication for data logging and real-time monitoring applications.
Designed for permanent installations and continuous operation scenarios, this power supply is essential for laboratory environments, production monitoring systems, and any application where extended operation without battery maintenance is required. The integrated RS-232 interface provides seamless PC connectivity for professional data acquisition and analysis.
MSRP:
$615.00
Get Today’s Best Price by Requesting a Custom Quote
Key Features
System Integration
Power Supply Function
- Continuous Operation: Eliminates battery maintenance
- Stable Power Delivery: Consistent 5V DC output
- Universal Compatibility: Works worldwide (100-240 VAC)
- Reliable Performance: Industrial-grade switching supply
- Cost Savings: Eliminates ongoing battery replacement costs
RS-232 Communication
- Direct PC Interface: Serial communication to computer
- Real-time Data: Live force measurements to PC applications
- Data Logging: Continuous data capture capability
- Software Integration: Compatible with spreadsheet and database applications
- Protocol Standard: Industry-standard RS-232 communication
Installation & Setup
- Connect AC power to universal input (100-240 VAC)
- Connect DC output to EDXtreme/Communicator II power input
- Connect RS-232 cable to PC serial port
- Configure communication parameters in PC software
- Verify operation using test utilities
Technical Specifications
| Specification | Value |
|---|---|
| Input Voltage | 100-240 VAC, 50/60 Hz |
| Output Voltage | 5V DC |
| Output Current | Sufficient for EDXtreme/Communicator operation |
| Power Type | Switching power supply |
| Communication Interface | RS-232 serial |
| Connector Types | AC input, DC output, RS-232 DB-9 |
| Operating Temperature | 0°C to +50°C (32°F to +122°F) |
| Enclosure | Industrial-grade housing |
| Certifications | CE, FCC, safety approvals |
| Mounting | Desktop/wall mount options |
Compatibility and Applications
Compatible Equipment
- EDXtreme RED Series: All capacity ranges requiring external power
- Communicator II Models: AWT05-506447, AWT05-509199, AWT77-506958
- Quick Check Devices: RED series tension meters
- PC Systems: Any computer with RS-232 serial port or USB-to-serial adapter
Primary Applications
- Laboratory Testing: Bench setups requiring continuous operation
- Production Monitoring: Manufacturing line integration
- Calibration Services: Professional testing environments
- Quality Control: Continuous monitoring systems
- Research & Development: Extended testing protocols
- Process Control: Industrial automation integration
Installation Scenarios
- Permanent Workstations: Fixed testing setups
- Production Lines: Integrated quality monitoring
- Calibration Labs: Professional measurement environments
- Research Facilities: Long-term testing applications
- Industrial Automation: Process control integration
- Data Acquisition Systems: PC-based monitoring setups
Key Benefits
Eliminates Battery Maintenance
Continuous operation without battery changes
Dual Functionality
Power and communication in one unit
Universal Compatibility
Works with worldwide voltage standards
Professional Integration
Ideal for permanent installations
Cost-Effective
Combines two essential functions
Reliable Operation
Industrial-grade components and construction
PC Connectivity
Direct interface for data acquisition
Reduced Downtime
Continuous operation capability
Comparison with Battery Operation
| Feature | Battery Operation | AWT25-501124 Mains Power |
|---|---|---|
| Operation Time | Limited (80 hours typical) | Continuous |
| Maintenance | Regular battery replacement | None required |
| PC Communication | Requires separate interface | Built-in RS-232 |
| Installation | Portable | Permanent/semi-permanent |
| Cost Over Time | Ongoing battery costs | One-time purchase |
| Reliability | Battery dependent | Mains power dependent |
Technical Considerations
When to Use Mains Power
- Extended operation periods: Longer than battery life
- Permanent installations: Fixed monitoring setups
- PC integration required: Data logging and analysis
- Laboratory environments: Bench testing applications
- Production monitoring: Continuous quality control
- Cost optimization: Eliminating battery replacement
Installation Requirements
- AC Power Access: 100-240 VAC outlet required
- Mounting Space: Desktop or wall mount location
- Cable Management: Proper routing of power and data cables
- Environmental Protection: Indoor or protected outdoor use
About Dillon
Dillon has been a pioneer in force-measurement and tension-testing equipment since 1937. The company’s products — from mechanical dynamometers to digital and wireless systems — are used worldwide in lifting, aerospace, construction, and energy industries.
Frequently Asked Questions
Ready to Experience the Reliability Difference?
Join the thousands of utility professionals who trust Dynamic Measurement Systems for their most critical force measurement needs. The Dillon AP Dynamometers are in stock and ready to ship today with fresh NIST-traceable calibration.
Availability
- All dynamometers typically ship same day from Houston facility
- Custom modifications require consultation with technical team
Technical Support
- Expert guidance available
- Application-specific recommendations provided
Order Now: +1-281-405-0606
Email: [email protected]
Emergency Service Available - Storm restoration and urgent project support with expedited processing and shipping.
Questions? Our technical experts are standing by to help you select the right equipment for your specific applications. No sales pressure, just professional guidance from people who understand your world.
